calibration instrument sales worldwide

Isotech PRTS

High Stability Reference Probes
Wide Temperature Ranges
High Stability Platinum Coil Elements
These industrial platinum resistance thermometers are ideal for field and lab use. Suitable for use as working standards in Dry Blocks and Liquid Baths or as high accuracy probes for our range of True Temperature Indicators.

All the thermometers are metal sheathed and both less fragile, and more affordable than the Isotech range of true Standard Platinum Resistance Thermometers that are used in laboratories and our found in our publication “Solutions for Primary and Secondary Laboratories”.

All the thermometers use handmade coil wound platinum sensing elements to give high accuracy and low drift. Isotech’s UKAS accredited lab can calibrate to the smallest of uncertainties.

- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Isotech 670

Useable Range -200°C to 670 °C
25.5 Ohm SPRT
Sensitivity:
  • 0.1Ω / °C (25.5Ω)
  • 0.4Ω / °C (100Ω)
Long term drift from 0.001°C / year depending on use
Models: 670SQ, 670SH, 670SL
Measuring Range: -200°C to 670°C
Nominal Resistance: 25.5Ω Ro or 100Ω Ro
Resistance Ratio: Wga>1.11807 as required by ITS-90
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Isotech 909/100 series

Useable Range -200°C to 670 °C
RTPW: 25.5Ω 100Ω
Nominal Resistance: 25.5Ω at 0°C 100Ω
Max. Current mA: 1 0.5
Nominal Sensitivity: 0.1 Ω/°C 0.4 Ω/°C
Resistance Ratio: Wga>1.11807 as required by ITS-90
Self-heating: 1mK / 25 microwatts
Stability: Depends upon the temperature
range of use. Typical annual stability, see the table on the next page. Internal leads: 4 wire-platinum
External Leads: Silver-plated multi-strand wires in a low-loss insulation cable terminating in gold-plated terminals.
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Isotech 935

Temperature Range:-50 to 250°C
Ro: 100Ω ±0.05Ω
Alpha: 0.003850 ±0.000005
Stability: 0.010 ohm/year
  • Diameter: 4mm
  • Length: 300mm
  • Sensing Length: 6mm
  • Lead Wires: 5' with 5-pin DIN
Calibration: A NIST Calibration Certificate can be provided at extra cost
Recommended Current: 1mA
Self-Heating Error at 1mA: 0.004°C
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Contacts

Tek Know Holding ApS
Island Brygge, 43, 2300,
Copenhagen S, Denmark,
e-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Tel.: +45 32 64 2626,
Fax: +45 32 64 2620