calibration instrument sales worldwide

SLP20

SLP20 Submersible Level Probe
  • Pressure ranges from 2.5 to 100 psi (0.17 to 7 bar)
  • Accurate to 0.5%
  • Measures levels up to 70m H2O (230 ft H2O)
  • Gauge and absolute versions
Operating Pressure Ranges
  • 2.5, 5, 15, 30, 50, and 100 psi (170, 350 mbar, 1, 2, 3, and 7 bar) gauge
  • 20, 30, 50, and 100 psi (1.3, 2, 3 and 7 bar) absolute Over Pressure 2x rated pressure to a maximum of 150 psi (10 bar)
Excitation Voltage
  • 10 VDC at nominally 1 mA
  • Supply limits of 2.5 to 15 VDC
Pulse Power Excitation
Recommended power on time before output samples 10ms
Output Voltage with 10 VDC supply
2.5 and 5 psi ranges 75 mV
All other ranges 100mV. (Output is ratiometric to supply)
Common Mode Voltage
Mid Rail (nominally) Output Impedance
5 kΩ
Input Impedance
10 kΩ
Accuracy
Combined eff ects of Non-linearity Hysteresis and repeatability ±0.5% FS BSL
Long Term Stability
±0.1% per year Typical
Compensated Temperature Range
0°C to 70°C (32°F to 158°F
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

RTX 1930 Series

RTX 1930 Series - Rangeable Submersible Pressure Transmitter
  • Ranges from 0.6 mH2O to 700 mH2O
  • Accuracy 0.06%
  • Fully welded 316 stainless construction
  • 4:1 Downranging
  • 4 to 20 mA output
Operating Pressure Ranges
Any zero based FS from 0.625 mH2O to 700 mH2O gauge
Standard Pressure Ranges
  • The standard Upper Range Limit (URL) can be configured by the customer to any intermediate range determined by the Range Adjustment Limits.
  • mH2O: 2.5, 5, 10, 15, 20, 35, 50, 100, 150, 200, 350, 700
  • ftH2O: 8, 16, 33, 50, 66, 115, 160, 335, 500, 650, 1150, 2300
  • Sensors can be provided with a pressure calibration at a down ranged FS, (e.g., 17 mH2O) at an additional cost (refer to Option C). Other units are software selectable e.g. mmH2O, ftH2O,inH2O, mbar, psi, bar.
Range Adjustment Limits
  • Downranging (4:1) — full 4 to 20 mA output change for any user zero based span setting up to the Upper Range Limit (URL) from 25 to 100% (URL).
  • Reverse (20 to 4 mA) — output can be inverted to give reducing current with increasing level, e.g. 0 to 10 mH2O (0 to 15 psi) range provides a 20 to 4 mA output as a power saving feature.
  • Elevation — the 4 mA output can be elevated within 0 to 75% of the Upper Range Limit (URL), e.g. 0 to 10 mH2O (0 to 15 psi) range can be elevated up to 7.5 to 10 mH2O (10 to 15 psi), with corresponding 4 to 20 mA output, e.g for water tower applications.
Overpressure
Standard Pressure Ranges (URL) can be exceeded by the following multiples with negligible effect on performance:
  • 6 x for ranges to 2.5 mH2O (4 psi)
  • 4 x for ranges above 2.5 mH2O (4 psi) (1400 mH2O (2000 psi) max)
Pressure Containment
  • 10 x for ranges to 2.5 mH2O (4 psi)
  • 6 x for ranges above 2.5 mH2O (4 psi) (1400 mH2O (2000 psi) max)
Output Signal
  • 4 to 20 mA proportional to the level input in normal operation
  • 3.8 to 20.5 mA proportional to the Loop Cal input in Remote Configuration Software (RCS) operation
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

RTX 1830 Series

PTX/PDCR 1830 Series - Depth and Level Pressure Sensors
  • Ranges from 0.75 mH20 to 600 mH20
  • Accuracy ±0.06%
  • Fully welded 17.5 mm titanium construction
  • Integral lightning surge arrestor
  • Polyurethane and hydrocarbon resistant cables
  • Full range of installation accessories
Operating Pressure Ranges
PDCR 1830/1840 (mV)
0.75, 1.5 mH2O gauge, 3.5, 7, 10, 15, 20, 35, 50, 70, 100, 150, 200, 350, 600 mH2O gauge and absolute
PTX 1830/1840 (mA)
Any zero based FS from 0.75 to 600 mH2O gauge and 3.5 to 600 mH2O absolute.
Elevated zero, compound and reversed output ranges available. Refer to GE Sensing for further information.
Other units may be specified e.g. ftH2O, inH2O, bar, mbar, kpa, kg/cm2
Overpressure
The operating FS pressure range may be exceeded by the following multiples with negligible effect on calibration:
  • 8 x for ranges up to 1.5 mH2O
  • 6 x for ranges above 1.5 to 3.5 mH2O
  • 4 x for ranges above 3.5 mH2O (1400 mH2O maximum)
Pressure Containment
  • 10 x for ranges up to 3.5 mH2O gauge
  • 6 x for ranges above 3.5 mH2O gauge (1400 mH2O maximum)
  • 200 bar for absolute ranges.
Media Compatibility
Fluids compatible with titanium (body), acetyl (nose cone) and polyurethane or Hytrel® 6108 (cable assembly)
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

PTX 1290 Series

PTX 1290 Series Wastewater Submersible Pressure Transmitter
  • Ranges 5, 10, 15 and 20 psig; higher ranges avail.
  • Accuracy ±0.25% FS BSL
  • Constructed of all welded titanium
  • Backed by a 5 year corrosion warranty
  • UL/CSA Intrinsically Safe Class I, Div I
Operating Ranges
Any range from 1.75 mH2O to 15 mH2O
Overpressure
The operating pressure range may be exceeded withnegligible effect on calibration by4x FS for ranges ≤ 7 mH2O2x FS for ranges > 7 mH2O (28 mH2O Maximum)
Pressure Media
Fluids compatible with Titanium, PTFE-coated nitrilerubber and Polyurethane
Excitation Voltage
9 to 28 Vd.c.
The minimum supply voltage (VMIN) which must appear across the pressure transmitter is 9V and is given by the following equation:- VMIN = VSUP - (0.02 x RLOOP)
Output Signal
4 to 20 mA
Accuracy
Combined effects of non-linearity, hysteresis and repeatability ±0.25% FS BSL
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

PTX 1230 Series

PTX 1230 Series - Depth and Level Pressure Sensors
  • Ranges 1 to 900 psig; 5 to 900 psia
  • Accuracy ±0.25% FS
  • Constructed of all welded titanium
  • Backed by a 5 year corrosion warranty
  • Vented polyurethane cable
  • Output: 2-wire 4-20 mA
  • FM/CSA Intrinsically Safe Class I, Div I
Operating Ranges
1, 2.5 psi (0.75, 1.5 mH2O) gauge
5, 10, 15, 20, 30, 50, 75, 100, 150, 200, 300, 500, 900 psi (3.5, 7, 10, 15, 20, 35, 50, 70, 100, 150, 200, 350, 600 mH2O) gauge or absolute Other pressure units can be specified.
Overpressure
10X for range 1 psig (0.75 mH2O)
8X 2.5 psi (1.5 mH2O)
6X 5 psi (1.5 to 3.5 mH2O)
4X for ranges above 5 psi (3.5 mH2O)
2000 psi (1400 mH2O) maximum
Pressure Media
Fluids compatible with titanium and polyurethane
Transduction Principal
Piezoresistive micromachined silicon strain gauge
Combined Error (Non-linearity, Hysteresis, and Repeatability)
±0.25% full scale (FS) base standard line (BSL)
Temperature Effects Over Compensated Range of 30°F to 86°F (-1°C to 30°C)
±2.0% FS total error band (TEB) for ranges below 5 psi (3.5 mH2O)
Resolution
Infinite
Insulation Resistance
100 MΩ @50 VDC
Relative Humidity
0 to 100%
Compensated Temperature Range
30°F to 86°F (-1°C to 30°C)
Operating Temperature Range
-5°F to 140°F (-20°C to 60°C)
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

PTX/PDCR 1730 Series

PTX/PDCR 1730 Series - Depth and Level Pressure Sensors
  • Ranges from 3.5 mH2O to 600 mH2O
  • Accuracy ±0.25%
  • Fully welded 17.5 mm 316 stainless construction
  • Pulse power operation
  • Polyurethane and hydrocarbon resistant cables
  • Full range of installation accessories
Operating Pressure Ranges
PDCR 1730 (mV)/PTX 1730 (mA) 5, 10, 15, 20, 30, 50, 75, 100, 150, 300, 500, 900 psi gauge
Overpressure
The operating FS pressure range can be exceeded by the following multiples with negligible effect on calibration.
4 x for 5 psi range
2 x for ranges 10 to 900 psi
Pressure Containment
10 x for 5 psi range
4 x for ranges up to 900 psi (2000 psi maximum)
Media Compatibility
Fluids compatible with 316 stainless steel, polyurethane (cable) and EPDM (nose cone).
Excitation Voltage
PDCR 1730 (mV)
10 V at 1 mA nominal Output is fully ratiometric to supply within 2.5 V to 12 V limits.
PTX1730 (mA)
9 to 30 VDC across terminals
For pulse power operation refer to technical note.
The minimum supply voltage (VMIN) which must appear across the pressure transmitter terminals is 9 V and is given by the following equation: VMIN = VSUP - (0.02 x RLOOP) Where VSUP is supply voltage in Volts, RLOOP is total loop resistance in Ohms
Output Signal
PDCR 1730
50 mV for 5 psi range
100 mV for ranges 10 psi and above
PTX 1730
4 to 20 mA proportional for zero to FS pressure
Common Mode Voltage - PDCR 1730
Nominally 50% of excitation voltage
Output Impedance - PDCR 1730
5 kΩ nominal
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.