XTP600 Series

Maximum Sample Pressure: Atmospheric to maximum of 0.3 MPa (3 bar)
Maximum Sample Temperature: 45°C max (higher temperature on request)
Accuracy: Better than ±1% of span
Dimensions: 213mm x 180mm x 140mm
Weight: 6.3kg
  • Best-in-class accuracy of less than 1% FS allows re-ranging with no need for re-calibration
  • Best-in-class zero or span stability: better than 0.25% of span per month
  • Innovative sensor design means no zero shift and eliminates background gas effects
  • Increased protection against contamination
  • Two 4-20 mA inputs for process variables allows active compensation
  • Two isolated outputs and a local display in an explosion-proof enclosure allow local as well as remote installation
  • Lowest cost of ownership due to minimal maintenance
Measurement Technology: Thermo-paramagnetic oxygen sensor
Gas: Process and non-condensing sample
Measurement Range: Selectable from 0 to 1% to 0 to 25% oxygen (other ranges available on request, eg 0-100% or suppressed ranges)
Response Time (T90): Standard response: 70 seconds, EN 50104: 45 seconds. For fast response consult factory
Repeatability: ±0.2% of span
Linearity: ±0.5% of span for ranges greater than 0-5%
<±1% of span for ranges less or equal to 0-5%
Zero Stability: ±0.25% of span per month
Span Stability: ±0.25% of span per month
Sample Flow Rate: 0.4 l/min for the sensor cell
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

XZR500 & XCU500

Maximum Sample Pressure: Depending on application
Maximum Sample Temperature: Up to 1300°C on request
Accuracy: Better than ± 2% of reading
Dimensions: 300x300x200 mm (control)
290x135x650 mm (sensor)
Weight: 10 to 15 kg depending on application
  • Reliable and repeatable measurements
  • Simple to maintain, easy to calibrate
  • Robust design
  • Quick and easy to install
  • Simple to use
Gas: Wet, dirty and hot
Measurement Range: 0.01 % to 25 % Oxygen
Response Time: < 15 sec for 90% of response step from calibration gas inlet
Repeatability: ± 0.1%
Fidelity: 1% per month
Linearity: Better than ± 1%
Sample Flow Rate: Flue gas at 0.5m/sec minimum rate
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

XZR400TS Series

Maximum Sample Pressure: 3 barg
Maximum Sample Temperature: 100°C
Accuracy: < 2% of reading
Dimensions and weight:
Wall mount version: 200 x 220 x 290mm, 5kg
Rack mount version: 19’’, 3U, 482.5 x 133 x 371.5mm, 10kg
Gas: Clean and Dry
Measurement Range: 0.01 ppm to 25% Oxygen (up to 100% optional)
Response Time: < 1 sec (for 90% of the step change)
Repeatability: ±0.1%
Linearity: Better than ±1%
Sample Flow Rate: 1 to 3 l/h with built-in fast loop
Atmospheric Pressure Compensation: Built-in as standard
- Price: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.
- This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Contacts

Tek Know Holding ApS
Island Brygge, 43, 2300,
Copenhagen S, Denmark,
e-mail: This e-mail address is being protected from spambots. You need JavaScript enabled to view it.

Tel.: +45 32 64 2626,
Fax: +45 32 64 2620